Size Exclusion Chromatography SEC/GPC

Size exclusion chromatography (SEC), also known as gel permeation chromatography (GPC) and gel filtration chromatography (GFC), is a chromatographic process in which analytes are separated according to size and structure. It is used to characterise natural and synthetic polymers, biopolymers, proteins and nanoparticles.

The largest molecules are the first to leave the separation column. The smaller the molecules are, the better they can penetrate the pores of the stationary phase and the later they are eluted from the column (see illustration).

Products

Price
Manufacturer
Brand
Product Type
Length
Internal Diameter
Particle Size
Chemistry
Chemistry Producers Term
Pore Size
USP Class
Carbon Load
Bet Surface Area [m2/g]
Endcapping
Column Type
Hardware Material
Hardware Type
Lower Molecular Weight
Upper Molecular Weight
Exclusion Limit
pH Minimum
pH Maximum
Temperature Maximum [°C]
Mode of Separation
Technology
Matrix
Number Theoretical Plates
Pressure Stability
Sort By

Items 991-1000 of 2701

Page
per page
SPX-215750P-4630
€2,470.00
SPX-215750LS-7830
€2,986.00
SPX-215750LS-7805
€1,229.00
SPX-215750LS-4630
€2,475.00
SPX-215750LS-4605
€938.00
SPX-211200-4602
€758.00
SPX-233150LS-7805
€873.00
SPX-225980-4625
€1,281.00
SPX-215750-4605
€770.00
SPX-215750-4625
€2,210.00
Sort By

Items 991-1000 of 2701

Page
per page

Technical Data

Basics

Stationary phases of the SEC

Either porous silica or polymer-based materials are used as stationary phases. In order to minimise adsorption or other undesirable interactions between the analyte and the stationary phase, some of these are modified or undergo special treatment during the manufacturing process. Polymer materials for the GFC are usually based on polymethacrylate or polyhydroxymethacylate. Styrene-divinylbenzene copolymer (PS-DVB) is often used for polymer-based GPC columns.

Mobile phases of SEC

Aqueous mobile phases are used in gel filtration chromatography (GFC). GFC is used as a bioseparation technique for the separation of proteins and other large biomolecules. Gel permeation chromatography (GPC), on the other hand, uses organic mobile phases to separate non-polar polymers (plastics).

SEC detectors

In principle, the same detectors can be used for size exclusion chromatography as in HPLC. In addition, light scattering and viscosity detectors are also used for polymer analysis in order to obtain specific molecular and structural information about the analyte. When SEC is combined with light scattering, viscometers and concentration detectors (known as triple detection), it can calculate absolute molecular weight, molecular size and intrinsic viscosity as well as provide information on macromolecular structure, conformation, aggregation and branching.

Reference materials for SEC

By using reference materials with known molecular size and distribution, the GPC system can be calibrated to allow precise analysis of molecular weights and molecular size distribution in a sample. Calibration standards are essential to regularly check the performance of the GPC system and ensure that results are consistent and reliable over time. These standards also help to optimise separation conditions and improve analytical accuracy, making them a critical component of high quality GPC analysis. MZ-Analysentechnhik GmbH offers you a wide range of different SEC reference materials from manufacturers such as Sigma Aldrich, Tosoh, Shodex or Waters.

Columns for the SEC/GPC

To select a suitable column, a few basic questions should be clarified first.

 

1. What is the polarity of the analyte and which solvents are suitable?

For very polar biomolecules, such as proteins or antibodies, purely aqueous buffers are often used as eluents. Silica gel has proven to be a suitable base material for this. For polar to medium polar polymers, aqueous or polar organic eluents or mixtures of both are used. The base material is often polymethacrylate or polyvinyl alcohol. For non-polar polymers for whose analysis purely organic eluents are used, styrene-divinylbenzene copolymers (PS/DVB) are usually used as stationary phases.

 

2. What is the molecular weight of my analyte?

The molecular weight of the analyte or its size in the solvent determines the pore size of the stationary phase. The absolute pore sizes range from about 25 to 30,000 Å, covering a molecular weight range of about 100 to > 20,000,000 Daltons. For samples with very different molecular weights, either several columns with different pore sizes can be connected in series or columns containing particles with different pore sizes can be used. These are often labelled "linear", "mixed gel" or "multipore gel".

In many cases, suitable pore sizes can be easily determined with the help of the usually very extensive calibration data provided by the manufacturers.

1. columns for organic mobile phases (GPC)

Manufacturer

Column lines

Characteristics

MZ-Analysentechnik GmbH

MZ-Gel SDplus(LS)

Base material: PS/DVB
Particle sizes: 3, 5 & 10 µm
Pore sizes: 50 - 106 Å & linear
Further features: LS suitable for light scattering detection

MZ-Analysentechnik GmbH

MZ-SuperFG

Base material: silica gel
Particle sizes: 7µm
Pore sizes: 100 - 4,000 Å & linear
Further features: For fluorinated solvents

Shodex™

K-800 Series
KD-800 Series
KF-800 Series

Base material: PS/DVB
Particle sizes: 6 - 18 µm
Pore sizes: 50 - 20,000 Å & "mixed-gel"
Other features: For efficient GPC separations

Shodex™

KF-600 Series
KF-400HQ Series
HK-400 Series

Base material: PS/DVB
Particle sizes: 3 - 18 µm
Pore sizes: 50 - 20,000 Å & "mixed-gel"
Other features: For fast and ultra-fast applications

Shodex™

LF Series

Base material: PS/DVB
Particle sizes: 6 µm
Pore sizes: Multi-pore gels
Other features: Very large linear calibration range

Shodex™

HT and UT Series

For high temperature applications up to 210 °C

Shodex™

HFIP Series

For HFIP as eluent

Tosoh Bioscience™

TSKgel Alpha
TSKgel SuperAW

Base material: Highly cross-linked polymethacrylate
Particle sizes: 4 - 13 µm
Pore sizes: 25 - >1,000 Å & "mixed-gel"
Further features: For polar and non-polar eluents

Tosoh Bioscience™

TSKgel H Series

Base material: PS/DVB
Particle sizes: 5 & 10 µm
Pore sizes: 15 - >1,000 Å & "multi-pore"
Further features: High temperature GPC up to 220°C

Sepax™

Mono GPC

Base material: PS/DVB
Particle sizes: 5 & 10 µm
Pore sizes: 100 - 1,000 Å & linear
Other features: High eluent compatibility

Macherey-Nagel™

Nucleogel GPC

Base material: PS/DVB
Particle sizes: 5 & 10 µm
Pore sizes: 50 -104 Å
Further features: Wide application range

Waters™

Styragel™
Ultrastyragel™

Base material: PS/DVB
Particle sizes: 5, 10 & 15-20 µm
Pore sizes: 50 -107 Å & linear
Further features: HT for high temperature GPC

SMT™

SMTgel

Base material: silica gel
Particle sizes: 5 & 10 µm
Pore sizes: 100 - 2000 Å & linear
Other features: Various surface modifications available

 

2. columns for aqueous mobile phases (GFC) and aqueous/organic mobile phases

Manufacturer

Column lines

Characteristics

Tosoh Bioscienace

TSKgel SW Series

Base material: silica gel
Particle sizes: 2 - 17 µm
Pore sizes: 125 - 450 Å & "mixed-gel"
Other features: Industry standard for protein analysis

Tosoh Bioscience

TSKgel PW Series

Base material: polymethacrylate
Particle sizes: 3 - 17 µm
Pore sizes: 125 - >1,000 Å & "multi-pore"
Other features: Wide application range for polar polymers

Shodex™

K-800 Series
KD-803 Series
KF-400 Series

Base material: Silica gel
Particle sizes: 3 - 7 µm
Pore sizes: 400 - 2,000 Å
Other features: For protein analyses

Shodex™

SB-800HQ Series

Base material: Polyhydroxymethacrylate
Particle sizes: 8 - 35 µm
Pore sizes: 100 - 30,000 Å & "mixed-gel"
Further features: For the analysis of polar polymers

Shodex™

LB-800 Series

Base material: Polyhydroxymethacrylate
Particle sizes: 6 - 13 µm
Pore sizes: 800 - 15,000 Å
Other features: For light scattering detection

Shodex™

GF-HQ

Base material: Polyvinyl alcohol
Particle sizes: 5 & 9 µm
Pore sizes: 180 - 10,000 Å
Further features: For aqueous as well as organic eluents

Sepax™

Unix
Zenix
SRT
SRT-10

Base material: silica gel
Particle sizes: 1.8 - 10 µm
Pore sizes: 80 - 2,000 Å
Other features: For proteins, mAb's, nucleic acids, virus, etc.

Sepax™

Unix-C
Zenix-C
SRT-C
SRT-10C

Base material: silica gel
Particle sizes: 1.8 - 10 µm
Pore sizes: 80 - 2,000 Å
Other features: For membrane proteins, derivatised mAb's, etc.

Mitsubishi Chem. Corp.™

MCI GEL™ CQP-Series

Base material: Hydrophilic polymer
Particle sizes: 10 µm
Pore sizes: 120 - 600 Å
Other features: For polar polymers, such as oligosaccharides or PEG

Supelco

Discovery® BIO GFC

Base material: silica gel
Particle sizes: 5 µm
Pore sizes: 100 - 2,000 Å
Other features: For the analysis of biomolecules

Waters™

Ultrahydrogel™

Base material: Polyhydroxymethacrylate
Particle sizes: 6 - 12 µm
Pore sizes: 120 - >2,000 Å & linear
Other features: For polar polymers

 

Contact Us

Fields marked with * must be filled in

The right column for you - we will be happy to support you individually

Competent consultants are always at your side. Write a message to our consultants, we will get back to you and give you individual support.

You will find:

Application support Application support
Availability and delivery times Availability and delivery times
Price information with individual conditions Price information with individual conditions
Certificates of analysis, MSDS, data sheets Certificates of analysis, MSDS, data sheets