Normal Phase Chromatography

Normal Phase Chromatography is the original type of liquid chromatography, as it was also used in the early years of chromatography. It can sometimes also be referred to as adsorption chromatography if the separation mechanism is based on adsorption due to the stationary phase selected. Normal phase chromatography is generally characterised by stationary phases with polar surface properties and a mobile phase with a non-polar character.

Products

Price
Manufacturer
Brand
Product Type
Length
Internal Diameter
Particle Size
Chemistry
Chemistry Producers Term
Pore Size
USP Class
Carbon Load
Bet Surface Area [m2/g]
Endcapping
Column Type
Hardware Material
Hardware Type
pH Minimum
pH Maximum
Temperature Maximum [°C]
Technology
Matrix
Particle Morphology
Number Theoretical Plates
Pressure Stability
Sort By

Items 181-190 of 7704

Page
per page
TFS-40310-259570xL
€16,500.99
TFS-40310-259570A
€11,289.25
TFS-40310-259370xL
€9,309.76
TFS-40310-259370A
€5,570.29
TFS-40310-259270xL
€6,246.00
TFS-40310-259270A
€3,213.12
TFS-40310-259070A
€1,325.58
TFS-40310-159570xL
€14,008.83
TFS-40310-159570A
€10,237.85
TFS-40310-159370xL
€8,517.38
Sort By

Items 181-190 of 7704

Page
per page

Technical Data

Basics

The stationary phases of normal phase chromatography

Unmodified silica gels or aluminium oxide particles are often used as stationary phases, as the adsorption effect is the main separation mechanism with these materials and can therefore be referred to as "true" adsorption chromatography.

Other materials that can be used in normal phase mode (i.e. with non-polar mobile phases) are specially modified silica gels (cyano, amino, diol, nitro), which will not be discussed in detail here. More detailed information can be found under the heading "Medium Polar Phase Chromatography".

Mobile phases of normal phase chromatography

Almost all common organic solvents and their mixtures can be used as mobile phases in normal phase chromatography, as long as they are not strong acids or bases. Aliphatic hydrocarbons, such as hexane or heptane, have the weakest elution power. As the polarity of the solvent increases, so does its elution power. Polar solvents used include acetic acid ethyl ester, acetone, THF or various aliphatic alcohols.

What is the separation in normal phase chromatography based on?

Due to the ability of the stationary phase to form hydrogen bonds, electrostatic and other intermolecular interactions with the analytes, retention in normal phase chromatography is based on the different degrees of adsorption of the analytes on the stationary phase. Polar analytes are therefore retained more strongly than non-polar analytes, as they are more able to enter into polar interactions with the stationary phase.

Contact Us

Fields marked with * must be filled in

The right column for you - we will be happy to support you individually

Competent consultants are always at your side. Write a message to our consultants, we will get back to you and give you individual support.

You will find:

Application support Application support
Availability and delivery times Availability and delivery times
Price information with individual conditions Price information with individual conditions
Certificates of analysis, MSDS, data sheets Certificates of analysis, MSDS, data sheets