S*Pure / Maxi-Clean

Maxi-Clean

Maxi-Clean cartridges are an alternative format for SPE. The materials are the same as the Extract-Clean cartridges, but with a polypropylene housing with both a female luer inlet and a male luer outlet tip. This enables the use of positive pressure by syringe or negative pressure by vacuum manifold.

Product Line

Products

Price
Brand
Product Type
Chemistry
Chemistry Producers Term
Volume [ml]
Bed Mass [mg]
Sort By sort-descending

Items 1-10 of 74

Page
per page
SP-5178320
€264.00
SP-5178319
€314.00
SP-5178326
€286.00
SP-5178174
€256.00
SP-5178171
€221.00
SP-5178157
€470.00
SP-5178153
€700.00
SP-5178152
€243.00
SP-5178148
€265.00
SP-5178135
€393.00
Sort By sort-descending

Items 1-10 of 74

Page
per page

Technical Data

Maxi-Clean Aminopropyl (NH2): Ideal for carbohydrates or generally with analyses containing hydroxyl functional groups

Maxi-Clean Florisil (FL): Referenced in many EPA methods; ideally suited for pesticides and metals

Maxi-Clean Florisil-PR (FL-PR): Ensures most inert batches for highly active compounds
 

Maxi-Clean Alumina Acidic (AL-A): Increase capacity for acidic compounds
 

Maxi-Clean IC-OH: Exchanges anions for hydroxide; may be used to remove or concentrate anions from samples and to increase pH of acidic samples; removes cations that form insoluble hydroxide salts
 

Maxi-Clean IC-H: Exchanges cations for hydrogen; may be used to remove or concentrate cations from samples and to reduce pH of basic samples
 

Maxi-Clean IC-Ag: Removes excess halides through formation of Ag-halide salts
 

Maxi-Clean IC-Ba: Removes excess sulfate through formation of BaSO4
 

Maxi-Clean IC-Na: Exchanges cations for sodium, may be used to remove or retain cations from sample without changing the pH of the sample
 

Maxi-Clean Chelate: Exchanges transition metals and divalent cations for sodium; may be used to remove or retain divalent cations and transition metals from sample
 

Maxi-Clean IC-RP: Removes surfactants, organic acids and other organic substrates; inorganic ions pass through

Reversed Phase

Phase

Particle size

Pore size

Carbon content

Endcapped

Features

Prevail C18

50 µm

60 Ã…

11 %C

+

100% water wettable

Standard C18

50 µm

60 Ã…

6 %C

+

Low carbon load

High-Capacity C18

50 µm

60 Ã…

17 %C

+

High carbon load

Large Pore C18

50 µm

150 Ã…

14 %C

+

Ideal for compounds > 1500 MW

Octyl (C8)

50 µm

60 Ã…

4.5 %C

+

Less retention than C18

Ethyl (C2)

50 µm

100 Ã…

5.5 %C

+

Less retention than C8

Normal Phase

Phase

Material

Particle size

Pore size

Carbon content

Endcapped

Features

Silica (Si)

Silica

50 µm

60 Ã…

N/A

N/A

Highly polar surface

Aminopropyl (NH2)

Silica

50 µm

60 Ã…

5.0 %C

-

Polar phase with slight anion exchange properties

Cyanopropyl (CN)

Silica

50 µm

60 Ã…

6.0 %C

+

Unique selectivity

Florisil (FL)

Magnesium Silicate

75-150 µm

60 Ã…

N/A

N/A

Highly polar surface

Florisil (FL-PR)

Magnesium Silicate

75-150 µm

60 Ã…

N/A

N/A

Specifically tested for chlorinated pesticides

Aluminia Acidic (AL-A)

Aluminium Oxide

130 µm

100 Ã…

N/A

N/A

Alumina washed with acid surface

Ion Exchange

Phase

Modification

Material

Counter Ion

Particle size

Exchange capacity

Retains

SCX

Benzene Sulfonic acid

Styrene-DVB

Hydrogen

50 µm

2.0 meq/mL

Cations

SAX

Tetramethyl Ammonium

Styrene-DVB

Acetate

50 µm

1.0 meq/mL

Anions

Ion Chromatography

Phase

Material

Counter Ion

Particle size

Exchange capacity

Molecular exclusion limit

Retains

IC-OH

Styrene-DVB

Hydroxide

50 µm

1.0 meq/mL

1.000 Da

Anions

IC-H

Styrene-DVB

Hydronium

50 µm

2.0 meq/mL

1.000 Da

Cations

IC-Ag

Styrene-DVB

Silver

50 µm

2.0 meq/mL

1.000 Da

Chloride, Iodide, Bromide

IC-Ba

Styrene-DVB

Barium

50 µm

2.0 meq/mL

1.000 Da

Sulfate

IC-Na

Styrene-DVB

Sodium

50 µm

2.0 meq/mL

1.000 Da

Cations

IC-Chelate

Styrene-DVB

Sodium

50 µm

0.4 meq/mL

1.000 Da

Polyvalent metal ions

IC-RP

Polystyrene

N/A

50 µm

N/A

N/A

Hydrophobic components

Downloads

Brochures

Technical Support

Contact Us

Fields marked with * must be filled in

The right column for you - we will be happy to support you individually

Competent consultants are always at your side. Write a message to our consultants, we will get back to you and give you individual support.

You will find:

Application support Application support
Availability and delivery times Availability and delivery times
Price information with individual conditions Price information with individual conditions
Certificates of analysis, MSDS, data sheets Certificates of analysis, MSDS, data sheets