SiliCycle Inc. / SiliaChrom

SiliaChrom

SiliaChrom columns exist in a wide range of particle sizes, dimensions and modifications. There are pH stable columns (pH range 0.8-12), columns for 100 % aqueous eluents, ion exchanger and chiral columns are available.

Product Line

Technical Data

Phase

Particle size

Pore size

Surface area

Carbon content

pH range

USP Code

Tmax

AQ C18

3, 5, 10 µm

100 Å

380 m²/g

18 %C

1.5-9.0

L1

60 °C

AQ C8

3, 5, 10 µm

100 Å

380 m²/g

14 %C

1.5-9.0

L7

60 °C

dt C18

2.5, 3, 5, 10 µm

100 Å

410-440 m²/g

18 %C

1.5-9.0

L1

60 °C

dt Si

3, 5, 10 µm

100 Å

410-440 m²/g

-

1.0-8.0

L3

45 °C

XT C18

3, 5, 10 µm

150 Å

200 m²/g

15 %C

1.5-12

L1

60 °C

XT Fidelity C18

3, 5, 10 µm

100 Å

380 m²/g

21 %C

1.5-12

L1

60 °C

SB C18

3, 5, 10 µm

150 Å

200 m²/g

12 %C

0.5-7.5

L1

60 °C

SB C18-300

5 µm

300 Å

80 m²/g

5 %C

0.5-7.5

L1

60 °C

SB C8

5 µm

150 Å

200 m²/g

7 %C

1-7.5.0

L7

60 °C

SB C8-300

5 µm

300 Å

80 m²/g

3 %C

1.0-7.5

L7

60 °C

XDB C18

5 µm

150 Å

200 m²/g

15 %C

1.5-9.0

L1

60 °C

XDB C8

5 µm

150 Å

200 m²/g

8 %C

1.5-9.0

L7

60 °C

XDB Si

5 µm

150 Å

200 m²/g

-

1.0-8.0

L3

45 °C

XDB1 C18

3, 5 µm

100 Å

380-400 m²/g

22 %C

1.5-10

L1

60 °C

XDB1 C18-300

5, 10 µm

300 Å

80 m²/g

8 %C

1.5-9.0

L1

60 °C

XDB1 C8

5, 10 µm

100 Å

380-400 m²/g

14 %C

1.5-8.5

L7

60 °C

XDB1 C8-300

5 µm

300 Å

80 m²/g

4 %C

1.5-8.5

L7

60 °C

XDB1 C4

5 µm

100 Å

380-400 m²/g

7 %C

1.5-8.5

L26

60 °C

XDB1 C4-300

3, 5, 10 µm

300 Å

80 m²/g

3 %C

2.0-8.0

L26

60 °C

XDB1 C1

5 µm

100 Å

380-400 m²/g

3 %C

1.5-8.5

L13

60 °C

XDB C1-300

5 µm

300 Å

80 m²/g

1 %C

2.0-8.0

L13

60 °C

XDB1 CN

5, 10 µm

100 Å

380-400 m²/g

5 %C

2.0-8.5

L10

60 °C

XDB1 CN-300

5 µm

300 Å

80 m²/g

3.5 %C

2.0-8.0

L10

60 °C

XDB1 Amino

5, 10 µm

100 Å

380-400 m²/g

7 %C

2.0-8.5

L8

45 °C

XDB1 Amino-300

5 µm

300 Å

80 m²/g

3.5 %C

2.0-8.0

L8

45 °C

XDB1 Phenyl

5 µm

100 Å

380-400 m²/g

12 %C

1.5-9.0

L11

60 °C

XDB1 Phenyl-300

5 µm

300 Å

80 m²/g

4.5 %C

2.0-8.0

L11

60 °C

XDB1 Diol

5 µm

100 Å

380-400 m²/g

5 %C

2.0-8.0

L20

45 °C

XDB1 Diol-300

5 µm

300 Å

80 m²/g

1 %C

2.0-8.0

L20

45 °C

XDB1 Si

3, 5, 10 µm

100 Å

380-400 m²/g

-

1.0-8.0

L3

45 °C

XDB1 Si-300

3, 5, 10 µm

300 Å

80 m²/g

-

2.0-8.0

L3

45 °C

XDB2 C18

3, 5, 10 µm

100 Å

380 m²/g

18 %C

1.5-9.0

L1

60 °C

SCX

3, 5, 10 µm

150 Å

200 m²/g

10 %C

2.0-8.5

L9

45 °C

SCX-300

3, 5 µm

300 Å

80 m²/g

3.5 %C

2.0-8.0

L9

45 °C

SAX

3, 5, 10 µm

100 Å

380 m²/g

6 %C

2.0-8.5

L14

45 °C

SAX-300

3, 5 µm

300 Å

80 m²/g

1 %C

2.0-8.0

L14

45 °C

HILIC

3, 5, 10 µm

100 Å

380 m²/g

8 %C

2.0-8.0

-

60 °C

HILIC-300

5 µm

300 Å

80 m²/g

2.5 %C

2.0-8.0

-

60 °C

RPC

5, 7, 10, 20 µm

-

750 m²/g

polymer

1.0-14

L21

-

Cellulose T-DPC

5, 10 µm

-

-

-

2.0-7.0

L40

40 °C

Cellulose T-MB

5, 10 µm

-

-

-

2.0-7.0

-

40 °C

Amylose T-DPC

5, 10 µm

-

-

-

2.0-7.0

L51

40 °C

SiliaChrom dt C18: Is a phase which is suitable for 100 % aqueous eluents. This phase has no metal impurities und shows good peak shapes for neutral, acidic and basic compounds.
 

SiliaChrom AQ C8 and C18: Has the same modification like SiliaChrom dt C18, but with a low content of metal impurities.
 

SiliaChrom SB C18 and C8: Are specially modified columns to protect the surface effectively against acidic attacks. Therefore, these phases can be used at pH values down to 0.5.
 

SiliaChrom XT C18 and XT C18 Fidelity: These phases have a hybrid surface to reduce the solubility of the silica gel at high pH values. For this reason, these columns can be used at pH values between 1.5 and 12. The difference between both phases is only in the carbon content.
 

SiliaChrom XDB C18 and C8: Due to the larger pores and a lower surface area, these phases show lower retention for large hydrophobic molecules. This makes them suitable for the analysis of barbiturates, vitamins, fatty acids and steroids.
 

SiliaChrom XDB1 Family: These phases possess an extremely dense bonding on the surface. This leads to a very low interaction with free silanols. However, these columns are not recommended for samples which are highly hydrophobic.
 

SiliaChrom XDB2 C18: Developed to avoid strong interactions with hydrophobic compounds.
 

SiliaChrom RPC: Is a polymer phase based on polystyrene divinylbenzene. This allows this phase to be used at pH values between 1 and 14.
 

SiliaChrom Amylose: This chiral phase is used for the separation of alkaloids, troponins, amines and beta blockers.
 

SiliaChrom Cellulose T-DPC: Is used for the chiral separation of alkaloids, troponins, amines and beta blockers.
 

SiliaChrom Cellulose T-MB: Is used for the chiral separation of aryl methyl esters and aryl methoxy esters.

Downloads

Brochures

Contact Us

Fields marked with * must be filled in

The right column for you - we will be happy to support you individually

Competent consultants are always at your side. Write a message to our consultants, we will get back to you and give you individual support.

You will find:

Application support Application support
Availability and delivery times Availability and delivery times
Price information with individual conditions Price information with individual conditions
Certificates of analysis, MSDS, data sheets Certificates of analysis, MSDS, data sheets