GL Sciences / InertCap

InertCap

InertCap™ is the brand name for GC columns from GL Sciences™. The columns exhibit very high inertness and cover a wide range of polarity and applications.

Products

Base Material
Price
Brand
Product Type
Length
Internal Diameter
Film Thickness [µm]
Chemistry
Chemistry Producers Term
USP Class
Temperature Maximum [°C]
Sort By

Items 11-20 of 417

Page
per page
1010-69449
€907.00
1010-69445
€695.00
1010-64968
€1,638.00
1010-20762
€675.00
1010-20742
€669.00
1010-20722
€590.00
1010-20662
€747.00
1010-20642
€628.00
1010-20622
€475.00
1010-20541
€762.00
Sort By

Items 11-20 of 417

Page
per page

Technical Data

Column name

Phase

Polarity

USP

Diameter

Film thickness

Tmax[1]

InertCap™-1

Dimethyl polysiloxane (100%)

Non-Polar

G2

0.18 mm
0.25 mm

0.32 mm

0.53 mm

0.18, 0.28 µm
0.10, 0.25, 0.40, 0.50,
1.0, 1.5, 5.0 µm
0.25, 0.40, 0.50,
1.0, 5.0 µm
1.0, 1.5, 2.0, 3.0, 5.0 µm

260-350 °C

InertCap™-1ms

Dimethyl polysiloxane (100%)

Non-Polar

G2

0.25 mm
0.32 mm

0.10, 0.25, 1.0 µm
0.25, 1.0 µm

300-350 °C

InertCap™-5

Diphenyl-
/dimethylpolysiloxane (5%/95%)

Non-polar

G27

0.18 mm
0.25 mm

0.32 mm
0.53 mm

0.18, 0.28 µm
0.10, 0.25, 0.40, 0.50, 1.0, 1.5 µm
0.25, 0.40, 0.50, 1.0 µm
1.0, 1.5, 2.0, 3.0, 5.0 µm

260-350 °C

InertCap™-5MS/Sil

Diphenyl (equiv.)-
/dimethylpolysiloxane (5%/95%)

Non-Polar

G27

0.25 mm
0.32 mm

0.10, 0.25, 0.50, 1.0 µm
0.10, 0.25, 0.50 µm

325-350 °C

InertCap™-5MS/NP

Diphenyl-
/dimethylpolysiloxane (5%/95%)

Non-polar

G27

0.18 mm
0.25 mm
0.32 mm

0.18 µm
0.10, 0.25, 0.50, 1.0 µm
0.10, 0.25, 0.50, 1.0 µm

325-350 °C

InertCap™-624

Cyanopropyl-phenyl-
/dimethylpolysiloxane (6%/94%)

Mid-polar

G43

0.25 mm
0.32 mm
0.53 mm

1.0, 1.4 µm
1.8, 3.0 µm
1.4, 3.0 µm

260 °C

InertCap™-1301

Cyanopropyl-phenyl-
/dimethylpolysiloxane (6%/94%)

Mid-polar

G43

0.25 mm
0.32 mm
0.53 mm

0.25, 0.50, 1.0 µm
0.25, 0.50, 1.0 µm
1.0 µm

260-300 °C

InertCap™-25

Diphenyl-
/dimethylpolysiloxane (25%/75%)

Mid-polar

G28

0.25 mm
0.32 mm
0.53 mm

0.25, 0.50, 1.0 µm
0.25, 0.50, 1.0 µm
1.0 µm

260-320 °C

InertCap™-35

Diphenyl-
/dimethylpolysiloxane (35%/65%)

Mid-polar

G42

0.25 mm
0.32 mm
0.53 mm

0.10, 0.50, 1.0 µm
0.10, 0.50, 1.0 µm
1.0, 1.5 µm

260-300 °C

InertCap™-1701

Cyanopropyl-phenyl-
/dimethylpolysiloxane (14%/86%)

Mid-polar

G46

0.25 mm
0.32 mm
0.53 mm

0.25, 0.50, 1.0 µm
0.25, 0.50, 1.0 µm
0.50, 1.0 µm

260-300 °C

InertCap™-17

Diphenyl-
/dimethylpolysiloxane (50%/50%)

Mid-polar

G3

0.25 mm
0.32 mm
0.53 mm

0.25 µm
0.15, 0.25 µm
1.0 µm

300-340 °C

InertCap™-17ms

Diphenyl-
/dimethylpolysiloxane (50%/50%)

Mid-polar

G3

0.25 mm
0.32 mm

0.25 µm
0.15, 0.25 µm

320-340 °C

InertCap™-210

Trifluoropropyl-methylpolysiloxane

Mid-polar

G6

0.25 mm
0.32 mm
0.53 mm

0.25 µm
0.25 µm
1.0 µm

220-260 °C

InertCap™-225

Cyanopropylmethyl-
/ phenylmethylpolysiloxane (50%/50%)

Mid-polar

G19

0.25 mm
0.32 mm
0.53 mm

0.25 µm
0.25 µm
0.50 µm

220-240 °C

InertCap™ Pure-WAX

Polyethylene glycol (PEG)

Polar

G16

0.25 mm
0.32 mm
0.53 mm

0.25, 0.50 µm
0.25, 0.50 µm
1.0 µm

240-260 °C

InertCap™ WAX

Polyethylene glycol (PEG)

Polar

G16

0.25 mm
0.32 mm
0.53 mm

0.25, 0.50 µm
0.25, 0.50 µm
1.0, 2.0, 3.0 µm

230-260 °C

InertCap™ WAX-HT

Polyethylene glycol (PEG)

Polar

G16

0.25 mm
0.32 mm
0.53 mm

0.25, 0.50 µm
0.25, 0.50 µm
1.0 µm

250-280 °C

InertCap™ FFAP

Polyethylene glycol (modified with
nitroterephthalic acid)

Polar

G35

0.25 mm
0.32 mm
0.53 mm

0.25, 0.50 µm
0.25, 0.50, 1.0 µm
0.25, 0.50, 1.0 µm

230-250 °C

InertCap™ Pesticides

5 % Diphenyl(equiv.)-
Dimethylpolysilphenylene siloxane

Low-Polar

G27

0.25 mm

0.20 µm

325-350 °C

InertCap™ Aquatic

Diphenyl-
/dimethylpolysiloxane (25%/75%)

Mid-Polar

G28

0.25 mm
0.32 mm
0.53 mm

1.0 µm
1.4 µm
2.0 µm

200-220 °C

InertCap™
Aquatic-2

Diphenyl-
/dimethylpolysiloxane (25%/75%)

Mid-polar

G28

0.25 mm
0.32 mm
0.53 mm

1.4 µm
1.8 µm
3.0 µm

260 °C

InertCap™ for Amines

Proprietary

N/A

N/A

0.32 mm

N/A

265-300 °C

InertCap™ CHIRAMIX

Mix of several
cyclodextrin derivatives

N/A

N/A

0.25 mm

0.25 µm

180-200 °C

[ 1 ] Depends on the film thickness and whether work is carried out at a constant temperature or with a gradient.

InertCap™-1:

  • Non-polar phase for general purpose
  • Wide application range

 

InertCap™-1ms:

  • General purpose column
  • Non-polar phase with low bleed and high inertness; ideal for GC/MS

 

InertCap™-5:

  • Optimal first choice column for a variety of general analyses such as pesticides and volatile compounds etc.

 

InertCap™-5MS/Sil:

  • Ultra low bleeding and high resistance by arylene technology
  • Ideal for GC/MS

 

InertCap™-5MS/NP:

  • Ultra low bleeding and excellent inertness; ideal for GC/MS

 

InertCap™-624:

  • Mid-polarity phase
  • Designed for the analysis of volatile organic compounds (VOC)
  • optimal for the analysis of “acetoaldehyde and  methanol in ethanol” defined in the Japanese Pharmacopoeia Sixteenth Edition

 

InertCap™-1301:

  • Mid-polarity phase
  • Compared to InertCap™ 25, polarity of InertCap™ 1301 is slightly lower
  • Unique selectivity

 

InertCap™-25:

  • Different selectivities compared to other medium polar columns
  • Wide application range

 

InertCap™-35:

  • Optimal for the analyses of semivolatile compounds or solvent
  • Stronger polarity than InertCap™ 25

 

InertCap™-1701:

  • Mid-polarity phase with stronger polarity than InertCap™-25
  • Optimal for screening analyses of pesticides

 

InertCap™-17:

  • Medium polar column with stronger polarity than InertCap™ 35
  • Optimal for general analyses and pesticides analyses

 

InertCap™-17ms:

  • Medium polar column with ultra low bleed; ideal for GC/MS
  • Optimal for microanalyses such as pesticides analyses

 

InertCap™-210:

  • Unique selectivity for polar compounds
  • Optimal for analyses of compounds containing phosphorous-nitrogen

 

InertCap™-225:

  • It strongly retains compounds with a high degree of unsaturation by dipole interactions
  • Useful for separating geometrical isomers of fatty acid methyl esters (FAMEs)

 

InertCap™ Pure-WAX:

  • Strong polar column with high inertness for the analyses of acidic compounds and/or basic compounds

 

InertCap™ WAX:

  • Slightly stronger polarity than InertCap™ Pure-WAX
  • Optimal for analyses of strong polar samples such as solvent

 

InertCap™ WAX-HT:

  • Strong polar column with increased temperature stability
  • Optimal for the analyses of polar samples

 

InertCap™ FFAP:

  • Strong polar column for the analysis of volatile fatty acids and other acidic compounds

 

InertCap™ Pesticides:

  • Especially designed for simultaneous analyses of pesticides with GC/MS

 

InertCap™ Aquatic:

  • Medium polar column for the analysis of volatile organic compounds (VOC) in water
  • Optimal for VOC simultaneous analyses by Purge and Trap

 

InertCap™ Aquatic-2:

  • Very similar phase to InertCap™ Aquatic, but with higher temperature stability
  • For certain compounds there are some selectivity differences compared to InertCap™ Aquatic

 

InertCap™ for Amines:

  • Excellent performances for C2 – C10 amines
  • Basic compounds can be perfectly eluted without being adsorbed in the column
  • Analyse general solvents such as alcohol along with amine compounds simultaneously, due to a unique phase technology

 

InertCap™ CHIRAMIX:

  • Specialized column for enantiomer separation
  • The chiral selector is a mixture of more than two kinds of cyclodextrin derivatives. This offers the possibility to analyze a wide range of compounds in a short time

Contact Us

Fields marked with * must be filled in

The right column for you - we will be happy to support you individually

Competent consultants are always at your side. Write a message to our consultants, we will get back to you and give you individual support.

You will find:

Application support Application support
Availability and delivery times Availability and delivery times
Price information with individual conditions Price information with individual conditions
Certificates of analysis, MSDS, data sheets Certificates of analysis, MSDS, data sheets