Agilent Technologies / Agilent-DB

Agilent-DB

DB is a brand name for GC columns manufactured by Agilent Technologiesâ„¢. The columns cover a very wide range of polarity and application and are very inert. All DB phases are bonded and cross-linked and solvent rinsable.

Products

Price
Product Type
Length
Internal Diameter
Film Thickness [µm]
Chemistry
Chemistry Producers Term
USP Class
Sort By sort-descending

Items 391-400 of 1099

Page
per page
AG-123-9334UI-INT
€1,063.00
AG-123-9334UI
€852.00
AG-123-9234-INT
€986.00
AG-123-9234E
€877.00
AG-123-9234
€782.00
AG-123-9134-INT
€986.00
AG-123-9134E
€877.00
AG-123-9134
€782.00
AG-123-8336-INT
€1,090.00
AG-123-8336
€864.00
Sort By sort-descending

Items 391-400 of 1099

Page
per page

Technical Data

DB-1:

  • Excellent general purpose column
  • Low bleed
  • Wide range of applications
     

DB-1ms:

  • Excellent general purpose column
  • Identical selectivity to DB-1
  • Very low bleed characteristics, ideal for GC/MS
  • Improved acid performance compared to standard 100% dimethylpolysiloxane columns
     

DB-5:

  • Excellent general purpose column
  • Low bleed
  • Wide range of applications
     

DB-5ms:

  • Non-polar phase with excellent inertness for active compounds
  • Very low bleed characteristics, ideal for GC/MS
     

DB-XLB:

  • Low polarity phase with exceptionally low bleed and unique selectivity
  • Excellent inertness for active compounds
  • Ideal for confirmational analyses and GC/MS
  • Excellent for pesticides, herbicides, PCBs and PAHs
     

DB-35:

  • Low bleed
  • Inert to active solutes
  • Ideal for confirmational analyses
     

DB-35ms:

  • Very low bleed characteristics, ideal for GC/MS
  • Excellent inertness for active compounds
  • Ideal for confirmational analyses
     

DB-17:

  • Mid polarity
  • Excellent for confirmational analyses
     

DB-17ms:

  • Very low bleed mid-polarity column, ideal for GC/MS
  • Excellent inertness for active compounds
  • Excellent choice for CLP pesticides
     

DB-225:

  • Excellent for separations of cis- and trans-fatty acid methyl esters (FAMEs)
     

DB-225ms:

  • Excellent for separations of cis- and trans-fatty acid methyl esters (FAMEs)
  • Low bleed
     

DB-23:

  • High polarity phase for separation of fatty acid methyl esters (FAMEs)
  • Excellent resolution for cis- and trans-isomers
     

DB-200:

  • Ideal for difficult-to-separate positional isomers
  • Unique interactions with compounds containing nitro, halogen and carbonyl groups
  • Low ECD bleed
     

DB-210:

  • High polarity phase
  • Excellent for US EPA Methods 8140 and 609
     

DB-1301:

  • Low/mid polarity
  • Exact replacement of HP-1301 and HP-1701
     

DB-1701:

  • Low/mid polarity
  • Exact replacement of HP-1301 and HP-1701
     

DB-WAX:

  • Lower temperature limit of 20 °C, improves resolution of low boiling point analytes, compared to other PEG-phases
  • Column-to-column reproducibility
     

DB-WaxFF:

  • Highly reproducible, specially tested microbore DB-Wax for fragrance analysis
     

DB-WAXetr:

  • PEG-phase for extended temperature range (etr)
  • Excellent column-to-column repeatability
     

DB-FFAP:

  • Nitroterephthalic acid modified polyethylene glycol phase designed for the analysis of volatile fatty acids and phenols
     

DB-1ht:

  • Specially processed for extended temperature limit of 400 °C
  • High temperature, polyimide-coated, fused silica tubing
  • Excellent peak shape and faster elution times for high boilers
     

DB-5ht:

  • Specially processed for extended temperature limit of 400 °C
  • High temperature, polyimide-coated, fused silica tubing
  • Excellent peak shape and faster elution times for high boilers
     

DB-17ht:

  • Extended upper temperature limit of 365 °C
  • High temperature, polyimide-coated, fused silica tubing
  • Excellent peak shape and faster elution times for high boilers
  • Improved resolution for triglycerides
  • Ideal for confirmational analyses
     

DB-Petro:

  • Configured for the analysis of petroleum process products
  • Suitable for PONA/PIANO analyses
     

DB-2887:

  • Specifically designed for simulated distillation using ASTM Method D2887
  • Rapid conditioning, fast run time and low bleed when compared to packed columns
     

DB-HT SimDis:

  • "Boiling point" phase for high temperature simulated distillation
  • Durable stainless steel tubing
  • Distillation range of C6 to C110+
  • Low bleed, even at 430 °C
     

DB-CLP 1 and DB-CLP 2:

  • Universal column pair designed for pesticides analyses
  • EPA Methods: CLP (Contract Lab Program) pesticides, 504.1, 505, 508.1, 551, 552.3, 8081B, 8082A, 8154A
  • Ideal for dual column, dual ECD GC analyses
  • Mid polarity stabilized phases provide fast and low bleed reliable analyses
  • Special testing includes pesticides for proof of performance and column to column reproducibility
  • DB-CLP1: Primary column; DB-CLP2: Confirmation column
     

DB-1701P:

  • Specifically designed and processed for the analysis of organochlorine pesticides
  • ECD tested to ensure minimal pesticide breakdown and low ECD bleed
     

DB-608:

  • Specifically designed for the analysis of chlorinated pesticides and PCBs
  • US EPA Methods: 608, 508, 8080
  • Excellent inertness and recoveries without pesticide breakdown
     

DB-EUPAH:

  • Specially designed for analysis of EU regulated PAHs
  • Individually tested with application-specific QC test probe mixture
  • Great resolution of critical isomers, e.g. benzo(b,j,k)fluoranthenes
  • Superb thermal stability for accurate analysis of high boiling PAHs, e.g. dibenzopyrenes
     

DB-UI 8270D:

  • Designed for EPA Method 8270D and other regulated GC/MS semivolatiles analysis
  • Special semivolatiles testing ensures poof of column to column performance for trace level analysis
  • Excellent 2,4-dinitrophenol response
  • Ultra inertness and low bleed
     

DB-5.625:

  • Specially processed to exhibit excellent inertness for EPA Semivolatiles Methods 625, 1625, 8270 and CLP protocols
  • Surpasses EPA performance criteria for semivolatiles
  • Inert for base, neutral and acidic compounds
  • High temperature limit with excellent thermal stability and low bleed
     

DB-Dioxin:

  • Specifically engineered for the analysis of polychlorinated dibenzodioxins (PCDDs) and dibenzofurans (PCDFs)
  • Resolves 2,3,7,8-TCDD and 2,3,7,8-TCDF from all other isomers in one run
     

DB-624 Ultra Inert:

  • Environmental volatile organic compounds (VOCs) methods
  • Excellent for US EPA Methods: 501.3, 502.2, 503.1, 524.2, 601, 602, 8010, 8015, 8020, 8240, 8260
  • Industrial chemical analyses – solvents, petrochemicals, specialty chemicals
  • Food and beverage – alcohols, fusel oils
  • Pharmaceutical residual solvents per USP <467>
  • Ultra inertness processing expands application range with excellent peak shape for low molecular weight acidic compounds
  • UI testing ensures premium performance column to column
  • Identical selectivity to the industry standard DB-624 – upgrade with no change in method required
     

DB-624:

  • Specifically designed for the analysis of volatile priority pollutants and residual solvents
  • No cryogenics needed for US EPA Method 502.2
  • Excellent for US EPA Methods: 501.3, 502.2, 503.1, 524.2, 601, 602, 8010, 8015, 8020, 8240, 8260, and USP 467
  • Excellent inertness for active compounds
     

DB-VRX:

  • Unique selectivity engineered for optimum resolution of volatiles analysis: US EPA Methods 502.2, 524.2 and 8260
  • No subambient cooling required to resolve the six "gases"
     

DB-502.2:

  • Available in 105 m for volatiles analyses
  • Excellent peak shape
     

DB-MTBE:

  • Low polarity stationary phase
  • Resolves MTBE from 2-methylpentane and 3-methylpentane for better quantitation
  • Engineered for purge and trap injection without the need for cryofocusing
     

DB-TPH:

  • Specifically designed for the analysis of total petroleum hydrocarbons (TPHs), soil analysis, and LUFT
  • Three analyses in one injection – gas range organics, diesel range organics and motor oil
     

DB-ALC1 and DB-ALC2:

  • Reliable blood alcohol analysis
  • Optimized primary and confirmation column pair for US blood alcohol analysis
  • Faster GC run times
  • Improved resolution of key ethanol/acetone peaks
     

DB-5ms EVDX:

  • Specially configured and tested for drugs of abuse confirmation
  • Drug test mix included: caffeine, glutethimide, lidocaine, phenobarbital, EDDP, methaqualone, methadone, cocaine, desipramine, carbamazepine
  • Consistent retention and peak shape
  • Low bleed for GC/MS analysis
     

DB-Select 624 UI for <467>:

  • Engineered to optimize pharmaceutical residual solvents analysis per USP Method <467>
  • Ultra inertness and low bleed
  • Resolution of USP regulated critical pairs, also separates benzene and 1,2-dichloroethane
  • UI testing ensures premium performance column to column
Column-Name

Phase

Polarity

USP

ID

Film thickness

Tmax[1]

DB-1

Dimethyl polysiloxane (100%)

Non-Polar

G1,
G2,
G9,
G38

0.05 mm

0.05, 0.20 µm

260‒360 °C

0.10 mm

0.10, 0.12, 0.20, 0.40 µm

0.15 mm

1.20 µm

0.18 mm

0.18, 0.20, 0.40 µm

0.20 mm

0.33, 0.80 µm

0.25 mm

0.10, 0.25, 0.50, 1.0 µm

0.32 mm

0.10, 0.12, 0.25, 0.50, 0.52, 1.0,
1.05, 1.2, 1.5, 2.0, 3.0, 5.0 µm

0.45 mm

1.27, 2.55 µm

0.53 mm

0.10, 0.15, 0.25, 0.50, 0.88, 1.0,
1.5, 2.65, 3.0, 5.0 µm

DB-1ms

Dimethyl polysiloxane (100%)

Non-Polar

G1,
G2,
G9,
G38

0.10 mm

0.10, 0.40 µm

340‒360 °C

0.18 mm

0.18 µm

0.20 mm

0.33 µm

0.25 mm

0.10, 0.25 µm

0.32 mm

0.10, 0.25 µm

DB-5

Diphenyl-/dimethylpolysiloxane
(5%/95%)

Non-Polar

G27

0.10 mm

0.10, 0.17, 0.33, 0.40 µm

260‒350 °C

0.15 mm

1.20 µm

0.18 mm

0.18, 0.40 µm

0.20 mm

0.20, 0.33 µm

0.25 mm

0.10, 0.25, 0.50, 1.0 µm

0.32 mm

0.10, 0.17, 0.25, 0.50, 0.52, 1.0,
1.05, 1.5 µm

0.45 mm

0.42, 1.27 µm

0.53 mm

0.25, 0.50, 0.88, 1.0, 1.5, 2.65,
3.0, 5.0 µm

DB-5ms

Phenyl-Arylene-Polymer
(equivalent to Diphenyl-
/dimethylpolysiloxane (5%/95%))

Non-Polar

G27

0.18 mm

0.18, 0.36 µm

300‒350 °C

0.20 mm

0.33 µm

0.25 mm

0.10, 0.25, 0.40, 0.50, 1.0 µm

0.32 mm

0.10, 0.25, 0.50, 0.52, 1.0 µm

0.53 mm

0.50, 1.0, 1.5 µm

DB-XLB

N/A

Low-Polar

N/A

0.18 mm

0.18 µm

320‒360 °C

0.20 mm

0.33 µm

0.25 mm

0.10, 0.25, 0.50, 1.0 µm

0.32 mm

0.25, 0.50 µm

0.53 mm

1.5 µm

DB-35

Diphenyl-
/dimethylpolysiloxane
(35%/65%)

Mid-Polar

G42

0.25 mm

0.25 µm

280‒320 °C

0.32 mm

0.25, 0.5 µm

0.53 mm

0.50, 1.0 µm

DB-35ms

Diphenyl-
/dimethylpolysiloxane
(35%/65%)

Mid-Polar

G42

0.18 mm

0.18 µm

320‒360 °C

0.20 mm

0.33 µm

0.25 mm

0.15, 0.25 µm

0.32 mm

0.25 µm

0.53 mm

0.50, 1.0 µm

DB-17

Diphenyl-
/dimethylpolysiloxane
(50%/50%)

Mid-Polar

G3

0.05 mm

0.10 µm

260‒300 °C

0.10 mm

0.10, 0.20 µm

0.18 mm

0.18, 0.30 µm

0.25 mm

0.15, 0.25, 0.50 µm

0.32 mm

0.15, 0.25, 0.50 µm

0.53 mm

0.25, 0.50, 1.0, 1.5, 2.0 µm

DB-17ms

Diphenyl-
/dimethylpolysiloxane
(50%/50%)

Mid-Polar

G3

0.18 mm

0.18 µm

320‒340 °C

0.25 mm

0.15, 0.25 µm

0.32 mm

0.25 µm

DB-225

Cyanopropylphenyl-
/dimethylpolysiloxane
(50%/50%)

Mid-Polar

G7

0.10 mm

0.10 µm

200‒240 °C

0.18 mm

0.20 µm

0.25 mm

0.15, 0.25 µm

0.32 mm

0.25 µm

0.53 mm

0.50, 1.0 µm

DB-225ms

Cyanopropylphenyl-
/dimethylpolysiloxane
(50%/50%)

Mid-Polar

G7

0.25 mm

0.25 µm

240 °C

0.32 mm

0.25 µm

DB-23

(50%-Cyanopropyl)-
methylpolysiloxane

Polar

G5

0.18 mm

0.20 µm

230‒260 °C

0.25 mm

0.15, 0.25 µm

0.32 mm

0.25 µm

0.53 mm

0.50 µm

DB-200

(35%-Trifluoropropyl)-
methylpolysiloxane

Mid-Polar

G6

0.25 mm

0.25, 0.50 µm

280‒320 °C

0.32 mm

0.25, 0.50 µm

0.53 mm

1.00 µm

DB-210

(50%-Trifluoropropyl)-
methylpolysiloxane

Polar

G6

0.25 mm

0.25, 0.50 µm

220‒260 °C

0.32 mm

0.25, 0.50 µm

0.53 mm

1.0 µm

DB-1301

Cyanopropyl-phenyl-
/dimethylpolysiloxane
(6%/94%)

Mid-Polar

G43

0.18 mm

0.40 µm

260‒300 °C

0.25 mm

0.25, 1.0 µm

0.32 mm

0.25, 1.0 µm

0.53 mm

1.0, 1.5 µm

DB-1701

Cyanopropyl-phenyl-
/dimethylpolysiloxane
(14%/86%)

Mid-Polar

G46

0.10 mm

0.10, 0.40 µm

260‒300 °C

0.18 mm

0.18, 0.40 µm

0.25 mm

0.15, 0.25, 0.50, 1.0 µm

0.32 mm

0.15, 0.25, 1.0 µm

0.53 mm

0.25, 0.50, 1.0, 1.5 µm

DB-WAX

Polyethylene Glycol

Polar

G14,
G15,
G16,
G20,
G39,
G47

0.05 mm

0.05, 0.10 µm

230‒260 °C

0.10 mm

0.10, 0.20 µm

0.18 mm

0.18, 0.30 µm

0.20 mm

0.20 µm

0.25 mm

0.15, 0.25, 0.50 µm

0.32 mm

0.15, 0.25, 0.50 µm

0.45 mm

0.85 µm

0.53 mm

0.25, 0.50, 1.0 µm

DB-WaxFF

Polyethylene Glycol

Polar

G16

0.10 mm

0.20 µm

240‒250 °C

DB-WAXetr

Polyethylene Glycol

Polar

G14,
G15,
G16,
G20,
G39,
G47

0.20 mm

0.40 µm

230‒280 °C

0.25 mm

0.25, 0.50 µm

0.32 mm

0.25, 0.50, 1.0 µm

0.53 mm

1.0, 1.5, 2.0 µm

DB-FFAP

Polyethylene Glycol
(modified with
Nitroterephthalic acid)

Polar

G25,
G35

0.10 mm

0.10 µm

250 °C

0.25 mm

0.25, 0.50 µm

0.32 mm

0.25, 0.50, 1.0 µm

0.45 mm

0.85 µm

0.53 mm

0.25, 0.50, 1.0, 1.5 µm

DB-1ht

Dimethylpolysiloxane (100%)

Unpolar

G1,
G2,
G9,
G38

0.25 mm

0.10 µm

400 °C

0.32 mm

0.10 µm

0.53 mm

0.17 µm

DB-5ht

Diphenyl-
/dimethylpolysiloxane
(5%/95%)

Unpolar

G27

0.25 mm

0.10 µm

400 °C

0.32 mm

0.10 µm

DB-17ht

Diphenyl-
/dimethylpolysiloxane
(50%/50%)

Mid-Polar

G3

0.25 mm

0.15 µm

340‒365 °C

0.32 mm

0.15 µm

DB-Petro

Dimethylpolysiloxane (100%)

Unpolar

N/A

0.20 mm

0.50 µm

325‒350 °C

0.25 mm

0.50 µm

DB-2887

Dimethylpolysiloxane (100%)

Unpolar

N/A

0.53 mm

3.0 µm

350 °C

DB-HT SimDis

Dimethylpolysiloxane (100%)

Unpolar

N/A

0.53 mm

0.10, 0.15 µm

400‒430 °C

DB-CLP 1 and DB-CLP 2

N/A

N/A

N/A

0.32 mm

0.25, 0.50 µm

340‒360 °C

DB-1701P

Cyanopropyl-phenyl-
/dimethylpolysiloxane
(14%/86%)

Low/Mid-Polar

G46

0.25 mm

0.25 µm

260‒300 °C

0.32 mm

0.25 µm

0.53 mm

1.0 µm

DB-608

N/A

N/A

N/A

0.18 mm

0.18 µm

260‒300 °C

0.25 mm

0.25 µm

0.32 mm

0.50 µm

0.45 mm

0.70 µm

0.53 mm

0.50, 0.83 µm

DB-EUPAH

Diphenyl-/dimethylpolysiloxane
(50%/50%) modified with an
aromatic selector

N/A

G51

0.18 mm

0.14 µm

320‒340 °C

0.25 mm

0.25 µm

0.32 mm

0.25 µm

DB-UI 8270D

N/A

N/A

N/A

0.18 mm

0.36 µm

325‒350 °C

0.25 mm

0.25, 0.50 µm

DB-5.625

N/A

N/A

N/A

0.18 mm

0.18, 0.36 µm

325‒350 °C

0.25 mm

0.25, 0.50, 1.0 µm

0.32 mm

0.25, 0.50 µm

DB-Dioxin

N/A

Polar

G48

0.25 mm

0.50 µm

325‒350 °C

DB-624 Ultra Inert

Cyanopropyl-phenyl-
/dimethylpolysiloxane
(6%/94%)

Mid-Polar

G43

0.18 mm

1.0 µm

260 °C

0.25 mm

1.4 µm

0.32 mm

1.8 µm

0.53 mm

3.0 µm

DB-624

Cyanopropyl-phenyl-
/dimethylpolysiloxane
(6%/94%)

Mid-Polar

G43

0.18 mm

1.0 µm

260‒280 °C

0.20 mm

1.12 µm

0.25 mm

1.4 µm

0.32 mm

1.8 µm

0.45 mm

2.55 µm

0.53 mm

3.0 µm

DB-VRX

N/A

N/A

N/A

0.18 mm

1.0 µm

260 °C

0.25 mm

1.4 µm

0.32 mm

1.8 µm

0.45 mm

2.55 µm

DB-502.2

N/A

N/A

N/A

0.25 mm

1.4 µm

260‒280 °C

0.32 mm

1.8 µm

0.45 mm

2.55 µm

0.53 mm

3.0 µm

DB-MTBE

N/A

Low-Polar

N/A

0.45 mm

2.55 µm

260‒280 °C

0.53 mm

3.0 µm

DB-TPH

N/A

N/A

N/A

0.32 mm

0.25 µm

290‒320 °C

0.45 mm

1.0 µm

DB-ALC1 and
DB-ALC2

N/A

N/A

N/A

0.32 mm

1.8 µm (for ALC1);


1.2 µm (for ALC2)

260‒280 °C

0.53 mm

3.0 µm (for ALC1);


2.0 µm (for ALC 2)

DB-5ms EVDX

N/A

N/A

N/A

0.20 mm

0.33 µm

325‒350 °C

DB-Select 624 UI for <467>

N/A

N/A

N/A

0.25 mm

1.4 µm

260 °C

0.32 mm

1.8 µm

0.53 mm

1.8 µm

[1] Abhängig von der Filmdicke und ob bei konstanter Temperatur oder mit einem Gradienten gearbeitet wird.

Contact Us

Fields marked with * must be filled in

The right column for you - we will be happy to support you individually

Competent consultants are always at your side. Write a message to our consultants, we will get back to you and give you individual support.

You will find:

Application support Application support
Availability and delivery times Availability and delivery times
Price information with individual conditions Price information with individual conditions
Certificates of analysis, MSDS, data sheets Certificates of analysis, MSDS, data sheets