HALO PCS 40% Discount

From now until 30.09.2024 you will receive a 40% introductory discount on all HALO PCS columns.

 

The HALO PCS series is a new addition to the HALO product lines. This new phase has a positively charged surface (PCS) to provide a better peak shape for basic compounds. This positively charged surface is based on the well-known fused-core technology from AMT (Advanced Materials Technology). The PCS product line is available with the modifications C18 in 90 and 160Å as well as with phenyl-hexyl in 90Å.

Products

Price
Brand
Length
Internal Diameter
Chemistry
Chemistry Producers Term
Pore Size
USP Class
Carbon Load
Bet Surface Area [m2/g]
Column Type
Sort By

Items 21-30 of 38

Page
per page
AMT-92812-717
€850.00 €510.00
AMT-92812-617
€760.00 €456.00
AMT-92812-417
€680.00 €408.00
AMT-9281X-717
€915.00 €549.00
AMT-9281X-617
€840.00 €504.00
AMT-9281X-417
€760.00 €456.00
AMT-92114-717
€895.00 €537.00
AMT-92114-617
€795.00 €477.00
AMT-92114-417
€720.00 €432.00
AMT-92113-717
€895.00 €537.00
Sort By

Items 21-30 of 38

Page
per page

Technical Data

Phase

Modification

Particle size

Pore size

Endcapping

C-Content

USP

Surface

pH range

Tmax

HALO PCS C18

positively charged surface

C18

2.7 µm

90 Å

+

7.5 %C

L1

125 m²/g

2.0 - 7.0

60°Ca

40°Cb

HALO PCS C18

positively charged surface

C18

2.7 µm

160 Å

+

5.1 %C

L1

90 m²/g

2.0 - 7.0

60°Ca

40°Cb

HALO PCS Phenyl-Hexyl

positively charged surface

Phenyl-Hexyl

2.7 µm

90 Å

+

6.1 %C

L11

125 m²/g

2.0 - 7.0

60°Ca

40°Cb

low pH; high pH

Applications

HALO 90 Å PCS C18, 2.7µm, 2.1x100mm

As shown in this basic drug screening with antidepressants, the HALO® Fused-Core® PCS technology tolerates a higher sample loading with basic substances compared to the competitor's fully porous C18 column. The positively charged surface (PCS) stationary phase is ideal for basic analytes when using low ionic strength mobile phases such as formic acid.

Peak Identities

1. Doxepin

2. Desipramine

3. Imipramine

4. Nortriptyline

5. Amitriptyline

6. Trimipramine

HALO 90Å PCS Phenyl-Hexyl, 2.7µm, 100x2.1mm

  • Higher sample loading of basic compounds with simultaneously lower proportion of the organic phase

Peak Identities

1. Doxepin

2. Nortriptyline

3. Amitryptyline

4. Trimipramine

Downloads

Brochures

Contact Us

Fields marked with * must be filled in

The right column for you - we will be happy to support you individually

Competent consultants are always at your side. Write a message to our consultants, we will get back to you and give you individual support.

You will find:

Application support Application support
Availability and delivery times Availability and delivery times
Price information with individual conditions Price information with individual conditions
Certificates of analysis, MSDS, data sheets Certificates of analysis, MSDS, data sheets