Manufacturer / Macherey-Nagel

Macherey-Nagel

Macherey-Nagel is producer of stationary phases for chromatography and manufactures HPLC and GC columns for a wide range of applications including chiral separations.

 

HPLC-Column Protection System - from Macherey-Nagel suitable for all analytical HPLC-columns with 1/16" fittings.

Read more

Products

Price
Manufacturer
Brand
Product Type
Length
Internal Diameter
Particle Size
Film Thickness [µm]
Chemistry
Chemistry Producers Term
Pore Size
USP Class
Carbon Load
Bet Surface Area [m2/g]
Endcapping
Column Type
Hardware Material
Hardware Type
pH Minimum
pH Maximum
Temperature Maximum [°C]
Mode of Separation
Technology
Pressure Stability
Sort By

Items 281-290 of 8709

Page
per page
MN-931220
€44.40
MN-931219
€51.50
MN-931218
€41.90
MN-931217
€37.70
MN-931216
€36.50
MN-931215
€31.70
MN-931211
€56.70
MN-931210
€40.60
MN-931208
€32.20
MN-931206
€47.00
Sort By

Items 281-290 of 8709

Page
per page

Technical Data

Filter

With the CHROMAFIL® series, Machery-Nagel offers high-quality products for solvent and sample filtration. All syringe filters are HPLC certified, offer an optimized filter geometry for fast, clean and simple filtration and are available in a variety of different membrane materials. In addition, Machery-Nagel's syringe filters are suitable for use with automated filtration systems, such as SOTAX or Zymark Benchmate™.

Type

Available Porosities

Available Sizes

Quantity[1]

Polyester (PET)

0.20 µm

0.45 µm

1.20 µm

13 mm[1]

25 mm

100/pk

PET with glass fibre prefilter (GF/PET)

1.0/0.20 µm

1.0/0.45 µm

25 mm

100/pk

RC with glass fibre prefilter (GF/RC)

1.0/0.20 µm

1.0/0.45 µm

25 mm

100/pk

Polytetrafluoroethylene (PTFE)

0.20 µm

0.45 µm

3 mm

13 mm

25 mm

100/pk

Hydrophilised polytetrafluoroethylene (H-PTFE)

0.20 µm

0.45 µm

13 mm

25 mm

100/pk

Cellulose Mixed Ester (MV)

0.20 µm

0.45 µm

25 mm

100/pk

Cellulose Acetate (CA)

0.20 µm

0.45 µm

13 mm

25 mm

100/pk

Cellulose Acetate (CA) (Sterile Filter)

0.20 µm

0.45 µm

25 mm

50/pk

Polyamide (PA) = Nylon

0.20 µm

0.45 µm

3 mm

13 mm

25 mm

100/pk

Polyethersulfones (PES)

0.20 µm

0.45 µm

5.0 µm

25 mm

100/pk

Polyvinylidene difluoride (PVDF)

0.20 µm

0.45 µm

13 mm

25 mm

100/pk

PVDF with glass fibre prefilter (GF/PVDF)

1.0/0.45 µm

25 mm

100/pk

Glass fibre (GF)

1.0 µm

13 mm

25 mm

100/pk

[1 ] Filters in the 25 mm size are always available as a big box in a quantity of 400 pieces per pack (except the sterile cellulose acetate filters).
[2] Only available with pore sizes of 0.2 and 0.45 µm.

Flash

With the Chromabond® Flash Cartridges, Machery-Nagel offers high-quality products for flash chromatography.  In addition to pre-packed cartridges, empty cartridges and a variety of different sorbents are available. Machery-Nagel also offers cartridges for some special flash chromatography systems.
 
General Specifications of the Chromabond® Flash Cartridges:

  • Organic solvent resistant, low bleed polypropylene cartridges, thick column walls, one piece body
  • Sophisticated length-to-diameter ratio for high plate numbers and excellent separation efficiencies    
  • Distribution of eluent stream via highly porous frits    
  • Good reproducibility
  • High pressure stability of 15 bar (12 bar for cartridges > 200 g)
  • All common RP and NP phases available on request

 
Chromabond® Flash RS cartridges:

  • Designed for use in Teledyne Isco CombiFlash® systems (Companion®, Rf etc.) without additional connectors or capillaries
  • Filled with standard silica, unmodified (SiOH) or endcapped octadecyl modified (C18 ec)
  • On request, all column types can be packed with any adsorbent from our program of  Chromabond® or spherical
  • Nucleodur® phases (please note that other packings often result in differing adsorbent weights)
  • Columns available in ten different dimensions (4 to 1600 g of weighed out sorbent)
  • Column connections: Up to RS 330: Luer lock inlet and outlet, RS800 and RS1600 Maxiluers

 
Chromabond® Flash BT cartridges:

  • Designed for use in the Biotage® Isolera™ systems without additional connectors or capillaries
  • Filled with unmodified standard silica (45 μm)
  • On request, all column types can be packed with any adsorbent from our program of Chromabond® or spherical 
  • Nucleodur® phases (please note that other packings often result in differing adsorbent weights)
  • Columns available in eight different dimensions (4 bis 330 g of weighed out Sorbent) 
  • With Luer-Lock column connections
  • Partly filled Chromabond® Flash BT cartridges (e.g., filled up to 80 %) are available on request. By removal of the top cap the sample can be applied directly onto the cartridges

 
Chromabond® Flash DL cartridges:

  • Empty cartridges for self-packing
  • Each cartridge comes with 3 filter elements: one already inserted, two more filters aside.
  • With Luer-Lock column connections
  • Columns available in eight different dimensions

 
Chromabond® Flash FM cartridges:

  • Designed for use in the Biotage® FlashMaster™ systems without additional connectors or capillaries
  • Filled with standard silica, unmodified (SiOH) or endcapped octadecyl modified (C18 ec)    
  • On request, all column types can be packed with any adsorbent from our program of Chromabond® or spherical Nucleodur® phases (please note that other packings often result in differing adsorbent weights)
  • Open-tubular inlet and male Luer outlet
  • Available in many column dimensions and filling sizes

Downloads

Brochures

Applications

Technical support

Contact Us

Fields marked with * must be filled in

The right column for you - we will be happy to support you individually

Competent consultants are always at your side. Write a message to our consultants, we will get back to you and give you individual support.

You will find:

Application support Application support
Availability and delivery times Availability and delivery times
Price information with individual conditions Price information with individual conditions
Certificates of analysis, MSDS, data sheets Certificates of analysis, MSDS, data sheets