CP-Sil 5 CB:

  • General purpose phase
  • Available in fused silica or UltiMetal
     

CP-Sil 5 CB for Formaldehyde:

  • Optimized for analysis of formaldehyde, water and methanol
  • Trace analysis of sulfur compounds and partial permanent gas analysis possible
     

CP-Sil 8 CB:

  • General purpose phase
  • Available in fused silica and UltiMetal
  • Low bleed and high column-to-column reproducibility
     

CP-Sil 13 CB:

  • Specially developed for the analysis of medium polarity compounds
  • Ideal for confirmational analyses using ECD (Electron Capture Detector)
     

CP-Sil 24 CB:

  • Specially suitable for analysis of amines, drugs and pesticides
  • Ideal for analysis using ECD
  • Excellent confirmation column in combination with CP-Sil 5 CB or CP-Sil 8 CB
     

CP-Sil 43 CB:

  • Separates aromatic from aliphatic hydrocarbons with selectivity equivalent to OV-255
     

CP-1301:

  • Ideal for analysis of herbicides, pesticides and many pharmaceutical products
  • High reproducibility and good inertness
     

CP-Sil 19 CB:

  • Ideal for many environmental, food and beverage, and pharmaceutical applications
  • Useful as confirmation column
     

CP-Wax 52 CB:

  • High resolution of low boiling point analytes
  • High polarity provides separations for a broad range of applications
  • Excellent reproducibility and temperature stability for a variety of EPA and ASTM methods
     

CP-Wax 58 FFAP CB:

  • Ideal for analysis of acidic compounds, such as phenols, underivatized and derivatized free fatty acids
  • Highest polarity bonded wax column for analyzing polar compounds
  • High inertness provides excellent peak shape
     

Petroleum columns:

CP-Sil PONA CB:

  • High resolution analysis of paraffins, olefins, naphthalenes and aromatics in complex hydrocarbon mixtures
  • Engineered for hydrocarbon analysis according to ASTM (DHA method)
  • Inert to polar compounds for highly accurate data
     

CP-Sil PONA für ASTM D 5134:

  • Optimized PONA analysis for ASTM D5134
  • Exact dimensions as specified in the ASTM method for full compliance
  • Inert to polar additives
     

CP-SimDist:

  • For simulated distillation analysis up to C100
  • Low bleed improves quantitation
  • High temperature polyimide coating extends lifetime
     

CP-SimDist UltiMetal:

  • Designed for ASTM D2887 and the extended D2887 method compliance
  • Low bleed
  • Extended analysis to C120 with maximum temperature of 450 °C
  • UltiMetal tubing for excellent durability
  • Excellent retention time repeatability and column lifetime due to special deactivation of UltiMetal surface
     

CP-Sil 2 CB:

  • Extremely low polarity bonded stationary phase
  • Superior replacement to squalane
  • Unique selectivity toward cyclic hydrocarbons
     

CP-TCEP for alcohols in gasoline:

  • Engineered for analysis of alcohols in gasoline
  • Excellent peak shape for accurate separations of alcohols
  • Unique selectivity separates benzene after n-dodecane
     

CP-Sil 5 CB for Sulfur:

  • Optimized for analysis of volatile sulfur compounds
  • Trace analysis of sulfur compounds to C7 mercaptan for high productivity
  • High inertness, elutes SO2 for high quality data and low detection limits
     

CP-Volamine:

  • Non-polar stationary phase with excellent stability and performance for samples containing water
  • Ideal for analyzing volatile amines like MMA, DMA and TMA (monomethyl, dimethyl and trimethyl amine)
     

CP-Sil 8 CB for Amines:

  • Optimized inertness performance for a broad range of amine compounds
  • Thermal stability up to 350 °C enables separations of amines up to C20 as well as alkanolamines

Pestizide- and PAK Columns

CP-Sil 8 CB for Pestizides:

  • Linear column response down to femtogram level for improved productivity
  • Can be used with on-column injection techniques
  • Excellent inertness
     

CP-Sil 19 CB for Pestizides:

  • Ideal as a confirmation column for reliable results
  • Specified for EPA and CLP analytes for ultimate compliance
  • Supplied with a coupled retention gap for on-column injection for best detection limits
     

CP-Sil PAH CB UltiMetal:

  • Separates all 16 PAHs according to EPA Method 610
  • High temperature, low bleed phase

Semivolatiles Columns:

CP-Sil 8 CB for PCB:

  • Engineered for the analysis of PCBs according to DIN method 51527
  • Ideal for trace level ECD detection of PCBs
  • High temperature stability provides low bleed and extended lifetime
     

CP-Sil 5/C18 CB for PCB:

  • Engineered for high resolution PCB analysis
  • Lower polarity than 100% polydimethylpolysiloxane due to its C18 substitution
  • Optimized column length for separation of critical isomer pairs: 28/31, 56/60, 149/118, 105/153/132 and 170/190
  • Provides high signal-to-noise ratios for ECD detectors
     

CP-Sil 88 for Dioxins:

  • High polarity stationary phase with specific selectivity for dioxins and dibenzofuran separations
  • Integrated retention gap eliminates leaks and extends column lifetime with splitless injections
  • 2,3,7,8-TCDD can be determined at low concentrations

Volatiles Columns:

CP-Select 624 CB:

  • EPA volatiles methods 524.2, 624 and 8015
  • Specified by Pharmacopoeia V.3.3.9 for residual solvents
  • Excellent column-to-column reproducibility and low bleed
     

CP-Select CB for MTBE:

  • Engineered for analysis of MTBE in reformulated gasoline
  • Unique selectivity for MTBE
  • Broad dynamic range for quantification of MTBE
  • Ideal as primary or confirmation column

Food, Flavors and Fragrances Columns:

CP-Sil 88:

  • High selectivity towards positional and geometric isomers for ease-of-use
  • Highly substituted cyanopropyl phase
  • Highest polarity, non-chemically bonded and stabilized
                    

CP-Sil 88 for FAME:

  • Optimized for analysis of FAME (Fatty Acid Methyl Ester) cis/trans isomers
  • Use for FAME separations in the C6 to C26 range
     

CP-Wax 57 CB:

  • Unique high polarity bonded wax column
  • Industry proven for the analysis of alcohols in the brewing and wine/spirits industry
  • Excellent inertness for optimum peak shape of alcohols and glycols
     

CP-Carbowax 400 for volatiles in alcohol:

  • Designed for the analysis of volatiles in alcoholic beverages
  • High resolution for amyl alcohols for accurate quality control
     

CP-Wax 57 CB for Glycols and Alcohols:

  • Optimized for the analysis of glycols, diols and alcohols
  • Unique, high polarity wax phase
     

CP-TAP CB for Triglycerides:

  • Engineered phase for detailed analysis of triglycerides
  • Separates complete triglyceride pattern in less than 16 minutes
  • Separation based on carbon number and degree of unsaturation
  • Stabilized phase for low bleed and enhanced column lifetime
  • Available in fused silica and UltiMetal
     

CP-FFAP CB for Free Fatty Acids in Dairy Products:

  • Ideal for flavors, aromas and free fatty acids C1‒C26
  • Separates C2‒C24 acids in one run without derivatization
  • Water and solvent resistant
     

CP-Chiralsil Val:

  • Designed for separations of optically active compounds including amino acids
  • Both antipode phases are available (D and L) for maximum versatility
  • Tested for separation of amino acid enantiomers
     

CP-Chirasil-Dex CB:

  • Homogeneous enantioselectivity throughout the column
  • High resolution factor between isomers across a broad application range
  • Chemically bonded phase for excellent longevity
  • Low elution temperature of polar compounds
  • Suitable for all injection techniques
     

CP-Cyclodextrin-β-2,3,6-M-19:

  • Unique selectivity for optical and positional isomer separations
  • High efficiency enables wide range of applications
  • Separates o-, m-, and p-xylenes
  • Excellent peak shape for underivatized polar compounds

PLOT-Columns:

CP-Al2O3/KCl und CP-Al2O3/Na2SO4:

  • Aluminum oxide PLOT columns offer high selectivity for separating ppm levels of C1‒C5 hydrocarbons in process streams
  • High capacity thick films
  • No need for sub-ambient cooling
  • Available in fused silica and UltiMetal
     

CP-SilicaPLOT:

  • No influence of water on retention times
  • Elution of CO2 and sulfur gases at ppm levels
  • Separates cyclopropane from propylene
  • Ideal for a wide range of applications such as COS in ethylene, freons, hydrocarbons, propylene and sulfur compounds
  • High selectivity for C1‒C4 isomers in the presence of water
  • No negative influence on retention or peak shape when water is present in the sample
  • Inert surface preparation results in no decomposition pentadienes or freons
     

CP-Molsieve 5Å:

  • Separate argon and oxygen at ambient temperature to reduce costs
  • High efficiency and symmetrical peaks
Column-Name

Phase

Polarity

USP

ID

Film thickness

Tmax[1]

CP-Sil 5 CB

Dimethyl polysiloxane (100%)

Non-Polar

G1, G2, G9

0.10 mm

0.10, 0.12, 0.40 µm

290‒350 °C

0.15 mm

0.12, 1.20, 2.0 µm

0.20 mm

0.11, 0.20, 0.33, 0.50, 0.80 µm

0.25 mm

0.10, 0.12, 0.25, 0.40, 1.0, 1.2 µm

0.32 mm

0.10, 0.12, 0.25, 0.40, 0.52, 1.0,  1.2, 3, 5 µm

0.53 mm

0.15, 0.50, 1.0, 1.5, 2, 3, 5 µm

CP-Sil 8 CB

Diphenyl-
/dimethylpolysiloxane (5%/95%)

Non-Polar

G27, G36

0.10 mm

0.10 µm

290‒350 °C

0.15 mm

0.12, 1.20 µm

0.20 mm

0.20, 0.33 µm

0.25 mm

0.10, 0.12, 0.25, 0.40, 1.0, 1,2 µm

0.32 mm

0.10, 0.12, 0.25, 0.40, 0.52, 1.0, 1.2, 5 µm

0.53 mm

0.15, 0.50, 1.0, 1.5, 2, 5 µm

CP-Sil 13 CB

Diphenyl-
/dimethylpolysiloxane (14%/86%)

Mid-Polar

N/A

0.15 mm

0.40 µm

290‒330 °C

0.25 mm

0.20, 0.40, 1.2 µm

0.32 mm

0.20, 0.40, 1.2 µm

0.53 mm

1.0, 2.0 µm

CP-Sil 24 CB

Diphenyl-
/dimethylpolysiloxane (50%/50%)

Mid-Polar

G3

0.25 mm

0.25, 0.50 µm

265‒300 °C

0.32 mm

0.25 µm

0.53 mm

0.50, 1.0 µm

CP-Sil 43 CB

Cyanopropyl-/phenyl-
/dimethylpolysiloxane
(25%/25%/50%)

Mid-Polar

G19

0.25 mm

0.20 µm

200‒225 °C

0.32 mm

0.20 µm

CP-1301

Cyanopropylphenyl-
/dimethylpolysiloxane (6%/94%)

Mid-Polar

G43

0.25 mm

0.25, 1.0 µm

265‒280 °C

0.32 mm

0.25, 1.0 µm

0.53 mm

1.0 µm

CP-Sil 19 CB

Cyanopropylphenyl-
/dimethylpolysiloxane (14%/86%)

Mid-Polar

G46

0.10 mm

0.20 µm

275‒300 °C

0.15 mm

0.50 µm

0.20 mm

0.20 µm

0.25 mm

0.15, 0.20, 0.25, 0.40, 1.0, 1.2 µm

0.32 mm

0.15, 0.20, 0.25, 0.40, 1.0, 1.2 µm

0.53 mm

0.50, 1.0, 2.0 µm

CP-Wax 52 CB

Polyethylenglykol (PEG)

Polar

G16, G39, G47

0.10 mm

0.10, 0.20 µm

250‒275 °C

0.15 mm

0.15, 0.25 µm

0.20 mm

0.20 µm

0.25 mm

0.15, 0.20, 0.25, 0.50, 1.2 µm

0.32 mm

0.15, 0.20, 0.25, 0.40, 0.50, 1.0, 1.2 µm

0.53 mm

1.0, 2.0 µm

CP-Wax 58 FFAP CB

Nitroterephthalic
acid modified
Polyethylene Glycol

Polar

G25, G35

0.20 mm

0.30 µm

250‒275 °C

0.25 mm

0.20 µm

0.32 mm

0.2, 0.5, 1.2 µm

0.53 mm

0.5, 1.0, 2.0 µm

CP-Sil 5 CB for Formaldehyde

Dimethyl polysiloxane (100%)

Non-Polar

N/A

0.32 mm

8.0 µm

300‒325 °C

CP-Sil PONA CB

Dimethyl polysiloxane (100%)

Non-Polar

N/A

0.21 mm

0.5 µm

250‒275 °C

0.25 mm

0.5, 1.0 µm

CP-Sil PONA for ASTM D 5134

Dimethyl polysiloxane (100%)

Non-Polar

N/A

0.21 mm

0.5 µm

250‒275 °C

CP-SimDist

Dimethyl polysiloxane (100%)

Non-Polar

G2

0.32 mm

0.10 µm

375‒400 °C

0.53 mm

0.10, 0.17 µm

CP-SimDist UltiMetal

Dimethyl polysiloxane (100%)

Non-Polar

G2

0.53 mm

0.06, 0.09, 0.11, 0.17, 0.53, 0.88, 1.2, 2.65, 5.0 µm

400‒450 °C

CP-Sil 2 CB

N/A

Non-Polar

N/A

0.25 mm

0.25 µm

200 °C

0.32 mm

0.25, 1.2 µm

0.53 mm

2.0 µm

CP-TCEP for alcohols in gasoline

N/A

Non-Polar

N/A

0.25 mm

0.40 µm

135‒140 °C

CP-Sil 5 CB for sulfur

Dimethyl polysiloxane (100%)

Non-Polar

N/A

0.32 mm

4.0 µm

300‒325 °C

CP-Volamine

N/A

Non-Polar

N/A

0.32 mm

N/A

265‒300 °C

CP-Sil 8 CB for Amines

Diphenyl- /dimethylpolysiloxane (5%/95%)

Non-Polar

N/A

0.15 mm

2.0 µm

325‒350 °C

0.25 mm

0.25, 0.50 µm

0.32 mm

1.0 µm

0.53 mm

1.0 µm

CP-Wax for volatile Amines and Diamines

N/A

N/A

N/A

0.32 mm

1.2 µm

220 °C

0.53 mm

2.0 µm

CP-Sil 8 CB for pestizides

Diphenyl-
/dimethylpolysiloxane (5%/95%)

Non-Polar

N/A

0.25 mm

0.12 µm

300‒325 °C

0.53 mm

0.25 µm

CP-Sil 19 CB for pestizides

Cyanopropylphenyl-
/dimethylpolysiloxane (14%/86%)

Mid-Polar

N/A

0.25 mm

0.20, 0.25 µm

260‒300 °C

0.32 mm

0.25 µm

0.53 mm

1.0 µm

CP-Sil PAH CB UltiMetal

N/A

N/A

N/A

0.25 mm

0.12 µm

400‒425 °C

CP-Sil 8 for PCB

Diphenyl-
/dimethylpolysiloxane (5%/95%)

Non-Polar

N/A

0.25 mm

0.25 µm

300‒325 °C

CP-Sil 5/C18 CB for PCB

N/A

Non-Polar

N/A

0.25 mm

0.10 µm

275‒300 °C

0.32 mm

0.10 µm

CP-Sil 88 for dioxins

N/A

Polar

N/A

0.25 mm

0.10, 0.20 µm

225‒270 °C

0.32 mm

0.13 µm

CP-Select 624 CB

Cyanopropylphenyl-

/dimethylpolysiloxane (6%/94%)

Non-Polar

G43

0.15 mm

0.84 µm

265‒280 °C

0.25 mm

1.4 µm

0.32 mm

1.8 µm

0.53 mm

3.0 µm

CP-Select CB for MTBE

N/A

N/A

N/A

0.25 mm

0.25 µm

200 °C

CP-Sil 88

Cyanopropyl- /phenylmethylpolysiloxane
(90%/10%)

Polar

G5, G8

0.25 mm

0.20 µm

225‒240 °C

0.32 mm

0.20 µm

CP-Sil 88 for Fatty acid methylester (FAME)

Cyanopropyl-/phenylmethylpolysiloxane
(90%/10%)

Polar

G8

0.25 mm

0.20 µm

225‒240 °C

CP-Wax 57 CB

Polyethylenglykol (PEG)

Polar

N/A

0.15 mm

0.12 µm

200‒225 °C

0.25 mm

0.20 µm

0.32 mm

0.20, 1.2 µm

0.53 mm

1.0, 2.0 µm

CP-Carbowax 400 for volatile compoands in alcohol

Polyethylenglykol (PEG)

Polar

G20

0.32 mm

0.20 µm

60‒80 °C

CP-Wax 57 CB for glycols and alcohols

Polyethylenglykol (PEG)

Polar

N/A

0.25 mm

0.20 µm

200‒250 °C

0.53 mm

0.50 µm

CP-TAP CB for Triglycerides

N/A

N/A

N/A

0.25 mm

0.10 µm

350‒370 °C

CP-FFAP CB for free fatty acids in milk products

N/A

N/A

G35

0.15 mm

0.25 µm

250‒275 °C

0.32 mm

0.30 µm

0.53 mm

1.0 µm

CP-Chiralsil Val

Optical Antipode D
Optical Antipode L

N/A

N/A

0.25 mm

0.08 µm

200 °C

0.25 mm

0.12 µm

CP-Chiralsil-Dex CB

Cyclodextrin modified 
Dimethyl polysiloxane (100%)

N/A

N/A

0.25 mm

0.25 µm

200 °C

0.32 mm

0.25 µm

CP-Cyclodextrin-β-2,3,6-M-19

N/A

N/A

N/A

0.25 mm

0.25 µm

225‒250 °C

0.32 mm

0.25 µm

CP-Al2O3/KCl and CP-Al2O3/Na2SO4

N/A

N/A

N/A

0.25 mm

4.0 µm

200 °C

0.32 mm

5.0 µm

0.53 mm

10.0 µm

CP-SilicaPLOT

N/A

N/A

N/A

0.25 mm

3.0 µm

225 °C

0.32 mm

4.0 µm

0.53 mm

6.0 µm

CP-Molsieve 5Å

N/A

N/A

N/A

0.25 mm

30.0 µm

350 °C

0.32 mm

10.0, 30.0 µm

0.53 mm

15.0, 50.0 µm

[1] Abhängig von der Filmdicke und ob bei konstanter Temperatur oder mit einem Gradienten gearbeitet wird.

Contact Us

Fields marked with * must be filled in

The right column for you - we will be happy to support you individually

Competent consultants are always at your side. Write a message to our consultants, we will get back to you and give you individual support.

You will find:

Application support Application support
Availability and delivery times Availability and delivery times
Price information with individual conditions Price information with individual conditions
Certificates of analysis, MSDS, data sheets Certificates of analysis, MSDS, data sheets